Showing posts with label electric appliance. Show all posts
Showing posts with label electric appliance. Show all posts

Wednesday, November 28, 2012

NFB ( NO FUSE BREAKER )


http://electricisa.blogspot.com/2012/11/nfb-no-fuse-breaker.html
NFB (no fuse breaker) is one component of the electrical safety overload and short circuit. then what's the difference with the MCB?
be patient, we will discuss shortly.
the  function can be seen from the above definition of the meaning of that is, as a means to disconnect ( break ) electrical current when the load handled by the these tools becomes overload or short circuit, or the current through it exceeds that limit has been set at the NFB.

difference between the NFB with MCB is the limit value of current that can be served by both ini.MCB tool used for smaller load is typically modest and still can not diubah.sedangkan NFB has a larger current limit and used to secure his load currents more large and in some types of NFB anyone can set its current limit, of course, the greater the value of the current limit higher price NFB
HOW NFB WORKS 
Under normal circumstances:
after the tool is set current limit permitted. pull the lever to the OFF position and Rev to the ON position, so that an electrical current can flow and supply expenses.
overcurrent / overload / shortcircuit conditions:
electric current that flows through the tool and exceed the specified limits, then the metal bimetallic temperature inside will rise and the curved or bent, so that the contacts will be disconnected and the lever will go to the center position or TRIP. to restore it to its original state should be scaled first lever to the OFF position and then raised to the ON position. of course after checking the load and circuit underneath
HOW TO INSTALL NFB
before we put the NFB we have to count the total electric current  flow on this tools. to calculate the amount of current we can look at the name plate of a load (motor pump) and summing the the amount. then we determine the diameter of the cable conductor cross-sectional area accordingly. then we select the amount of NFB that will be used,
installation of equipment is series assembled on the top of  circuit and before the motor (load).


Tuesday, November 27, 2012

MCB ( MINIATUR CIRCUIT BREAKER )

ELECTRICISA.BLOGSPOT.COM MCB
MCB ( MINIATUR CIRCUIT BREAKER)  is an electrical device that is designed in such a way as to secure an electricity network from harm overload and short circuit.
FUNCTION MCB:

MCB serves to cut off power automatically if the power is delivered exceeds the limit value. This MCB is on / off, and can also serve as the main switch in the house. If the MCB is in a state bargainser off, then all the power in the house was halted. The switch is normally turned off when the repairs will be carried out electrical installations in the home.

MCB is a safety net that works on the principle of Bimetal, with some elements of the operation are:
1. Terminal trip (Bimetal)
2. Electromagnetic trip (coil)
3. Arc extinguishing
4. mechanisms of termination
By construction, the MCB has two ways of termination, namely: termination by heat and by electromagnetic.
1. Termination by the heat carried by the bimetallic rods, which are: combination of two different metals expansion coefficient of metal. If there is more flow due to overload, the bimetal will bend due to the heat and will push the breaker lever to release the mechanical lock. This causes the MCB trip.
2. Termination by ektromagnetik performed by the coil, if a short circuit occurs then the coil will be induced and the surrounding area there is a magnetic field that will pull the lever shaft and operate the breaker. To avoid the effects of melting, the high heat sparks that can occur when the termination will be muted by extinguishing arc (arc-shute) and sparks that arise will go through the blades of the arc-shute.
An automatic safety advantage is that it can be used again immediately after the termination, the automatic safety clutch freeway because there is otomatic clutch can not be used again if problem not improved.
The nature of the MCB are:
a. Load current can be considered when the heat generated heat in excess of permitted
b. Short circuit current can be decided without any slowdown
c. After the repair, the MCB can be reused.

The workings of MCB
1. Based on the heat. At MCB are bimetal plate (mix two different metals heat expansion coefficient). Bimetal will fold if there is excessive heat through. Bimetallic plates are curved because the heat will move the lever and the breaker will disconnect electric current.
2. Based on electromagnetic. Termination of electric current carried by the coil method is contained in the MCB. In the event of excessive current (MCB limit) will be induced so that the coil generates a magnetic field that will pull the lever breaker, so contact the MCB will be disconnected.

The size of the ability to decide MCB electrical current depends on the specifics of each MCB. For example, for a capacity of 2A MCB MCB will then work cut electric current when an electric current through the MCB exceed 2A. Each installation must take full account of the power requirements of each installation is installed.
It should be noted also for use in power installations that use the 3 phase occurs when the MCB trip (interference), the third MCB connected to each phase (RST) to open / end together.



Monday, November 26, 2012

DIRECT CURRENT ELECTRICAL MOTOR

http://electricisa.blogspot.com/direct current electrical motor
direct current electrical motor  DC motors / direct current, as the name implies, uses a direct current indirect / direct-unidirectional. DC motors are used in special applications where high torque ignition or acceleration over a broad speed range.this is another article about electric motor while we have discuss alternating current electrical motor.
Figure 3 shows a DC motor which has three main components:
• Pole field. Simply put, the interaction of the two magnetic poles will cause the rotation of a DC motor. DC motor has a stationary field poles and armature that moves in the space between the poles bearing field. A simple DC motor has two field poles: north and south poles. The magnetic lines of force extend across the opening between the poles from north to south. For motors larger or more complex consists of one or more electromagnets. Electromagnetic receive electricity from an outside power source as the field structure.
• Dinamo. If the current goes through the armature, it will become an electromagnet. Cylindrical dynamo, connected to the countershaft to drive the load. For the case of a small DC motor, the armature rotates in a magnetic field formed by the poles, to the north and south magnetic poles change locations. If this happens, the current is reversed to switch poles north and south dynamo.
• commutator. This component is mainly found in DC motors. Its purpose is to reverse the direction of the electric current in the armature. commutator also helps in the transmission of current between the armature and resources.
The main advantage is the speed of DC motor is easy to control and does not affect the quality of power supply. DC motors can be controlled by adjusting:
• armature voltage - increasing the armature voltage will increase the speed.
• Flow field - reducing the field current will increase the speed.

DC motors are available in many sizes, but their use is generally limited to a few low speed, low to moderate power usage, such as machine tools and rolling mills because of problems with mechanical commutation at a larger size. Also, they are restricted for use only in areas that are clean and not dangerous because the risk of sparking at the brushes. DC motors are also relatively expensive compared to AC motors.

The relationship between speed, field flux and armature voltage is shown in the following equation:

Electromagnetic force: E = KΦN

Torque: T = KΦIa

Where:
E = electromagnetic force developed in the armature terminals (volts)
Φ = flux field is directly proportional to the field current
N = speed in RPM (revolutions per minute)
T = torque electromagnetic
Ia = armature current
K = constant equation

DC Motor Types / Unidirectional Flow

a. Separate power DC motor / Separately Excited, If the field current is supplied from a separate source, it is called a separate power source DC motor / separately excited.

b. DC motors own resources / Self Excited: shunt motor. In a shunt motor, the field winding (shunt field) is connected in parallel with the armature winding (A). Therefore the total line current is the sum of the field current and armature current.

Here's about the speed of a shunt motor (ETE, 1997):
• Speed ​​is not constant in practice depends on the load (up to a certain torque as speed decreases, see Figure 4) and is therefore suitable for commercial use with a low initial load, such as machine tools.
• Speed ​​can be controlled by inserting resistance in series with the armature arrangement (reduced rate) or by inserting resistance in the field current (increasing speed).

c. Own power DC motors: motor series. In a series motor, the field winding (shunt field) connected in series with the armature winding (A). Therefore, the same field current to the armature current.

Here's about the speed of the motor series (Rodwell International Corporation, 1997; LM Photonics Ltd, 2002):
• Speed ​​is limited to 5000 RPM.
• It must be avoided running series motor with no load because the motor will accelerate.
Series motors are suitable for applications that require high starting torque, such as cranes and hoists.
d. Motor DC Compound / Combined.
DC compound motor is a combination of series and shunt motors. In this motor, the field winding (shunt field) connected in parallel and in series with the armature winding (A) as shown in Figure 6. Thus, the motor has a starting torque nice and steady pace. The higher the percentage of incorporation (ie, percentage of field windings are connected in series), the higher starting torque that can be handled by this motor. For example, the incorporation of 40-50% makes the motor suitable for hoists and cranes, motors standard compound (12%) do not match
fuft..thats LOL all article about electric is make me addict but its fun to share with all readers,thanks 

ALTERNATING CURRENT ELECTRICAL MOTOR

http://electricisa.blogspot.com/alternating current electric motor
alternating current electric motor  using an electric current that reverses direction at regular intervals. AC electric motor has two basic electrical parts: a "stator" and "rotor"

The stator is the stationary electrical component. The rotor is the rotating electrical component rotates the motor shaft. The main advantage of DC motors over AC is that the speed of an AC motor is more difficult to control. To overcome this disadvantage, AC motors can be equipped with a variable frequency drive to increase control while reducing its speed. Motor is an induction motor is the most popular in the industry because of its reliability and easier maintenance. AC induction motors are inexpensive (half or less than the price of a DC motor) and also provide power to weight ratio is quite high (about twice a DC motor).

Types of Motor AC / Alternating Flow-Back

a. Synchronous motor. Synchronous motor is an AC motor that works at a fixed speed frequency of the system. These motors require direct current (DC) for power generation and has a low starting torque, and therefore synchronous motor is suitable for applications that start with low loads, such as air compressors, motors and generators frequency changes. Synchronous motors are able to improve the power factor of the system, so it is often used in systems that use a lot of electricity.

The main components of a synchronous motor is
• Rotor. The main difference between synchronous motor with an induction motor is that the rotor synchronous machines running at the same speed as the rotation of the magnetic field. This is possible because the magnetic field of the rotor is no longer induced. The rotor has permanent magnets or DC-excited, which was forced to lock in a certain position when confronted with another magnetic field.
• Stator. The stator produces a rotating magnetic field which is proportional to the frequency supplied.

This motor rotates at synchronous speed, which is given by the following equation (Parekh, 2003):

Ns = 120 f / P

Where:
f = frequency of the supply frequency
P = number of poles

b. Induction motor. Induction motors are the most common motors used in various industrial equipment. Its popularity is due to the design, which is simple, inexpensive and easily available, and can be directly connected to an AC power source.

Component of induction motor has two main electrical components:
• Rotor. Induction motors use two types of rotor:
- Squirrel cage rotor consists of a thick conductor rods are embedded in parallel slots plots. These bars are short-circuited at both ends by means of short-circuiting rings.
- A wound rotor has three-phase windings, double layer and distributed. Many poles as the stator. Three phases digulungi wire on the inside and the other end connected to a small ring attached to the stem as a brush attached to it.
• Stator. The stator is made of a number of stampings with slots to carry three-phase windings. It is wound for number of poles. The rolls were spaced at 120 degrees geometry.

Classification of induction motor

Induction motors can be classified into two main groups (Parekh, 2003):
• Single-phase induction motor. This motor has only one stator winding, operates with single-phase power supply, has a squirrel cage rotor, and require a tool to turn the bike. So far this bike is the most common type of motor used in home appliances, such as fans, washing machine and clothes dryer, and for the use of up to 3 to 4 Hp.
• three-phase induction motors. Rotating magnetic field produced by a balanced three-phase supply. These motors have high power capabilities, can have a squirrel cage or wound rotor (although 90% had a squirrel cage rotor), and the ignition itself. It is estimated that about 70% of the motor industry uses this type, for example, pumps, compressors, conveyor belts, power lines, and a grinder. Available in sizes 1/3 to hundreds of horsepower.

Induction motor speed

Induction motor works as follows: Electricity is supplied to the stator, which produces a magnetic field. This magnetic field moves around the rotor at synchronous speed. Rotor currents produce secondary magnetic field, which is trying to fight the stator magnetic field, which causes the rotor to rotate. However, in practice, the motor never runs at synchronous speed but the "base rate" is lower. The difference between the two speeds is the "slip / slide" that increases with increasing load. Slip only occurs in an induction motor. To avoid slip ring can be fitted a sliding / slip ring, and the motor is called "motor slip ring / slip ring motor".

The following equation can be used to calculate the percentage of slip / slide (Parekh, 2003):

% Slip = (Ns - Nb) / Ns x 100

Where:
Ns = synchronous speed in RPM
Nb = base speed in RPM

The relationship between load, speed and torque
 graph torque vs. speed three-phase AC induction motor with the current set. When the motor (Parekh, 2003):
• Start turns lights are flame high initial currents and low torque ("pull-up torque").
• Achieve 80% of full speed, the torque is at the highest level ("pull-out torque") and the current begins to drop.
• At full speed, or synchronous speed, torque and stator currents down to zero.
also read article about direct current electrical motor

ELECTRIC MOTOR


http://electricisa.blogspot.com/electric-motor
electric motor is an electromagnetic device that converts electrical energy into mechanical energy. This mechanical energy is used for, for example, rotating impeller pump, fan or blower, driving a compressor, lifting materials, etc. in the industry and is also used in household electrical appliances (such as mixers, electric drill, fans).

Mechanism of action for all types of electric motors are generally the same:
• An electric current in a magnetic field will experience a force.
• If the current carrying wire is bent into a circle / loop, then both sides of the loop, ie at right angles to the magnetic field, will get a force in the opposite direction.
• pair of forces creates playlists / torque to rotate the spindle.
• These motors have multiple loops on dynamo to provide a more uniform torque and magnetic field generated by the coil arrangement called the electromagnetic field.

In understanding an electric motor, it is important to understand what is meant by the motor load. Load refers to the rotary power output / torque in accordance with the required speed. Expenses generally be categorized into three groups:
• constant torque load, is the load which the output power varies with the speed of operation, but the torque does not vary. Examples of constant torque loads are conveyors, rotary kilns, and constant displacement pump.
• Load with variable torque, is the torque load that varies with the speed of operation. Examples of variable torque loads are centrifugal pumps and fans (torque varies as the square of the speed).
• Constant power load, a load torque change with demand and inversely proportional to the speed. An example for a constant power load tools are machines.

ELECTRIC MOTOR can be divided into two groups based on the use of electric current. the direct current electric motor and alternating current electric motors